Wire and Cable
Industrial Lighting > Wire and Cable
15kV
MV Primary UD
EPR Cable
15kV
Primary
UD Cable Jacketed
25kV
MV Primary UD
EPR Cable
25kV
Primary
UD Cable Jacketed
Aluminum or Copper Conductor.
EPR Insulation.
Bare Copper Concentric Neutrals.
Polyethylene Jacket.
Aluminum or Copper Conductor.
TRXLP Insulation.
Bare Copper Concentric Neutrals. Polyethylene
Jacket.
Aluminum
or Copper Conductor.
To be used at 25,000 volts
or less and at conductor
temperatures not to exceed 105°C
for normal operation.
Aluminum or Copper Conductor.
Predominantly used for primary
underground distribution; suitable
for use in wet or dry locations,
direct burial, underground duct.
35kV
MV Primary UD
EPR Cable
35kV
Primary
UD Cable Jacketed
AAC
All Aluminum Conductor - Bare
ACSR
Aluminum Conductor.
Aluminum or Copper Conductor.
To be used at 35,000 volts or
less and at conductor
temperatures not to exceed 105°C
for normal operation.
Aluminum or Copper Conductor.
Meets ANSI/ICEA S-94-649.
TRXLP Insulation.
Bare Copper Concentric Neutrals.
Used primarily for overhead
transmission and primary and
secondary distribution, where
ampacitymust be maintained and
a lighter conductor is desired,
Steel Reinforced - Bare.
Used as bare overhead
transmission cable and as
primary and secondary
distribution cable.
Covered
Line Wire
Category
5e
Plenum Cable
Category
5e
Riser Cable
Category
6
Plenum Cable
Aluminum Conductor.
Polyethylene or Crosslinked
Polyethylene Covering. Used
primarily for overhead secondary
distribution lines.
CMP
FR low smoke PVC Jacket
Solid Annealed Copper Conductors
Thermoplastic Insulation.
Meets UL 444 • UL 1666
Solid Annealed Copper Conductors
Thermoplastic Insulation.
May be run in plenums or
may be used in the place of
CMR, CMG, CM, CMX cables.
600
Volts. Copper Conductor
Thermoplastic Insulation/SIM
Nylon Sheath. Heat, Moisture,
Gasoline, and Oil Resistant.
Also Rated MTW and THWN-2
SIM Technology® for easier pulling.
Aluminum
Conductors.
Polyethylene or Crosslinked
Polyehtylene Insulation.
To be used at voltages of 600
volts phase-to-phase or less.
Triplex
600V
Secondary UD
Type
TC
Power Cable - THHN
Type
TC
Power Cable - THHN
Type
TC
Control Cable-THHN
Aluminum
Conductors.
Cross-linked Polyethylene
(XLP) Insulation. Meets or
exceeds all applicable
requirements of ICEA S-105-692.
Copper
Conductors with
PVC/Nylon Insulation Rated THHN.
Heat, Moisture and Sunlight
Resistant PVC Outer Jacket.
Type TC Power Cable.
600 Volt. RoHS.
Used
to supply power to motors.
600 Volt. Copper Conductors
with PVC/Nylon Insulation
Rated THHN. Overall Heat,
Moisture and Sunlight
Resistant PVC Jacket. RoHS.
Type
TC Control Cable.
600 Volt. Copper Conductors.
PVC/Nylon Insulated Singles
Sizes 16 AWG through 10 AWG.
Overall PVC Jacket.
Heat, Moisture and Sunlight
Resistant. RoHS.